Friedrich Logo Background

CAD/BIM

  • Up to 13.5 IEER / 10.6 EER
  • Up to 3.3 COP
  • Two-Stage Cooling
  • Variable Frequency Drive
  • 3 Phase Models
  • PlusOne® ServiceSmart
  • Nominal Sizes: 15-20 Tons
Unit of Measure

Type

N/A Package HP

Gross Cooling Capacity

N/A 240000 Btu/hr70.3 kW20 TR

EER

N/A 9.5

IEER

N/A 12.5

Nominal CFM

N/A 8000 ft³/min3775 L/s

AHRI Rated CFM

N/A 8200 ft³/min3870 L/s

AHRI Net Cooling Capacity

N/A 240000 Btu/hr70.3 kW

Net Sensible Capacity

N/A 188000 Btu/hr55.1 kW

Net Latent Capacity

N/A 52000 Btu/hr15.2 kW

Minimum Circuit Ampacity

N/A 208-230V Belt Drive-VFD High: 114 A 208-230V Belt Drive-VFD Low: 107 A 208-230V Belt Drive-VFD Medium: 114 A 460V Belt Drive-VFD High: 51 A 460V Belt Drive-VFD Low: 47 A 460V Belt Drive-VFD Medium: 51 A 575V Belt Drive-VFD High: 42 A 575V Belt Drive-VFD Low: 39 A 575V Belt Drive-VFD Medium: 42 A

Maximum Overcurrent Protection

N/A 208-230V Belt Drive-VFD High: 150 A 208-230V Belt Drive-VFD Low: 125 A 208-230V Belt Drive-VFD Medium: 150 A 460V: 60 A 575V: 50 A

Voltage

N/A 3 / 208-230V / 60Hz 3 / 460V / 60Hz 3 / 575V / 60Hz

Weight

N/A 208-230V Belt Drive-VFD High: 1894 lb [859 kg] 208-230V Belt Drive-VFD Low: 1865 lb [846 kg] 208-230V Belt Drive-VFD Medium: 1894 lb [859 kg] 460V Belt Drive-VFD High: 1894 lb [904 kg] 460V Belt Drive-VFD Low: 1865 lb [846 kg] 460V Belt Drive-VFD Medium: 1894 lb [859 kg] 575V Belt Drive-VFD High: 1894 lb [859 kg] 575V Belt Drive-VFD Low: 1865 lb [846 kg] 575V Belt Drive-VFD Medium: 1894 lb [859 kg]

Shipping Weight

N/A 208-230V Belt Drive-VFD High: 1994 lb [904 kg] 208-230V Belt Drive-VFD Low: 1965 lb [891 kg] 208-230V Belt Drive-VFD Medium: 1994 lb [904 kg] 460V Belt Drive-VFD High: 1994 lb [904 kg] 460V Belt Drive-VFD Low: 1965 lb [891 kg] 460V Belt Drive-VFD Medium: 1994 lb [904 kg] 575V Belt Drive-VFD High: 1994 lb [904 kg] 575V Belt Drive-VFD Low: 1965 lb [891 kg] 575V Belt Drive-VFD Medium: 1994 lb [904 kg]

Depth

N/A 85 29/32 in2182 mm

Width

N/A 152 1/4 in3667 mm

Height

N/A 57 1/8 in1451 mm

N/A

  • New cooling system design to meet higher IEER
  • Removable indoor blower design with VFD
  • Convertible airflow to enhance application flexibility
  • Standard hinged panels for faster and easier access
  • Internally sloped condensate drain pan with condensate overflow sensor
  • Tube and fin coils designed for easy cleaning
  • Standard phase monitor for increased reliability
  • Controls options include easy communication via BACnet, LonWorks, or Modbus