- Cooling Efficiency: 15.2 SEER2/11.5 EER2
- Heating Efficiency: 81% AFUE6
- Refrigerant Type: R-454B
- Nominal Sizes 2 to 5 Tons [7.0 – 17.6 kW]
- Rated Cooling Capacities: 22.8 to 56 kBTU
- EcoNet® Enabled: Yes
- Compressor Type: Two-Stage Scroll
- Evaporator Coil Type: MicroChannel
- Condenser Coil Type: MicroChannel
- Airflow Type: Convertible
- Blower Motor Type: Constant CFM
- Ultra Low NOx Option: No
- Low NOx Option: Yes
- 1-Phase Option: Yes
- 3-Phase Option: Yes
- Stainless Steel Heat Exchanger: Yes
- Compatible Thermostat: Single-Stage 24V
- PlusOnes:
- PlusOne® Diagnostics1: The Rheem Contractor App and built-in EcoNet® & Bluetooth®2 technology, makes monitoring, troubleshooting and repairing the product easier than ever before
- PlusOne® Ignition System – Proven Direct Spart Ignition (DSI) for reliability and longevity
- PlusOne® Refrigerant Detection System™3- Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring
1Bluetooth functionality applies to the heating section only.
2The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.
3Factory installed on 3.5, 4 and 5 ton models. For R-454B equipment with a refrigerant charge less than 3.9 lbs (≈1.8 kg or ≈62.6 oz), a refrigerant detection system is not required by the UL 60335-2-40 standard.
- Specifications
- Cooling Performance
- Heating Performance
- Compressor
- Outdoor Coil
- Indoor Coil
- Outdoor Fan
- Indoor Fan
- Filter
- Dimensions
- Features
Voltage |
N/A 208/230 V |
Frequency |
N/A 60 Hz |
Number of Phases |
N/A 1 |
Outdoor Sound Rating |
N/A 81 dB |
Refrigerant Charge |
N/A 81 oz2296 g |
Minimum Circuit Ampacity |
N/A 35 |
Minimum Overcurrent Protection Device Size |
N/A 40 |
Maximum Overcurrent Protection Device Size |
N/A 50 |
Shipping Weight |
N/A 515 lb234 kg |
Weight |
N/A 229 kg505 lb |
Gross Cooling Capacity |
N/A 48500 Btu/h14.21 kW |
EER2 |
N/A 11.5 |
SEER2 |
N/A 15.2 |
Nominal CFM |
N/A 1600 ft³/min755 L/s |
AHRI Rated CFM |
N/A 1525 ft³/min720 L/s |
AHRI Net Cooling Capacity |
N/A 45500 Btu/h13.33 kW |
Net Sensible Cooling Capacity |
N/A 33300 Btu/h9.76 kW |
Net Latent Cooling Capacity |
N/A 14200 Btu/h4.16 kW |
Net System Power |
N/A 3.9 kW |
Heating Input (1st Stage / 2nd Stage) |
N/A 56000/80000 Btu/h16.41/23.44 kW |
Heating Output (1st Stage / 2nd Stage) |
N/A 45360/64800 Btu/h13.29/18.99 kW |
Temperature Rise Range |
N/A 25-55 ºF13.9-30.6 ºC |
AFUE |
N/A 81 % |
Steady State Efficiency |
N/A =-N/A= % |
No. Burners |
N/A 4 |
No. Stages |
N/A 2 |
Gas Connection Pipe Size |
N/A 0.5 in12.7 mm |
Type |
N/A Double-Stage Scroll |
No. Stages |
N/A 1 |
Fin Type |
N/A Louvered |
Tube Type |
N/A MicroChannel |
MicroChannel Depth |
N/A 1 in25.4 mm |
Face Area |
N/A 15.98 ft²1.48 m² |
Rows |
N/A 1 |
FPI |
N/A 23 |
Fin Type |
N/A Louvered |
Tube Type |
N/A MicroChannel |
MicroChannel Depth |
N/A 1 in25.4 mm |
Face Area |
N/A 7.07 ft²0.66 m² |
Rows |
N/A 1 |
FPI |
N/A 20 |
Refrigerant Control |
N/A TX Valves |
Drain Connection No. |
N/A 1 |
Drain Connection Size |
N/A 0.75 in19.05 mm |
Type |
N/A Propeller |
No. Used |
N/A 1 |
Diameter |
N/A 24 in609.6 mm |
Drive Type |
N/A Direct |
No. Speeds |
N/A 1 |
CFM |
N/A 4300 ft³/min2029 L/s |
No. Motors |
N/A 1 |
Horsepower |
N/A 1/3 hp |
Motor RPM |
N/A 1050 |
Type |
N/A FC Centrifugal |
No. Used |
N/A 1 |
Diameter |
N/A 12x9 in305x229 mm |
Drive Type |
N/A Direct |
No. Speeds |
N/A Multiple |
No. Motors |
N/A 1 |
Motor HP |
N/A 1 hp |
Motor RPM |
N/A 1050 |
Motor Frame Size |
N/A 48 |
Type |
N/A Field Supplied |
Furnished |
N/A No |
No. Filters |
N/A 2 |
Recommended Size |
N/A 1x16x30 in25x406x762 mm |
Depth |
N/A 46 11/18 in |
Width |
N/A 55 25/32 in |
Height |
N/A 41 in |
N/A
|