CAD/BIM
- Cooling & Heating Efficiency: 15.2 SEER2/11.7 EER2/7.8 HSPF2
- Refrigerant Type: R-454B
- Nominal Sizes: 1.5 to 5 Tons [TBD kW]
- Cooling & Heating Capacities: 17.1 to 54 kBTU
- Sound Ranking1: As low as 72 dB
- ENERGY STAR® Certified2: Yes
- EcoNet® Enabled: No
- Compressor Type3: Two-Stage
- Condenser Coil Type: 7mm
- Features: Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
Refrigerant Detection System™4: Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring - Limited Warranty*:
Parts: 5 Years
Conditional Compressor: 10 Years (registration required)
*For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
1Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product.
2Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR. Ask your contractor for details or visit EnergyStar.gov.
3The 1.5 ton model features a single-stage compressor.
4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).
Type |
N/A Heat Pump |
Nominal Capacity |
N/A 18000 Btu5.28 kW1.5 TR |
Refrigerant Type |
N/A R-454B |
Refrigerant Furnished oz. |
N/A 83 |
Compressor Type |
N/A Scroll |
Sound Level |
N/A 73 dB |
Weight |
N/A 163 lb |
Voltage |
N/A 208 to 230 V |
Number of Phases |
N/A 1 |
Frequency |
N/A 60 Hz |
Maximum Overcurrent Protection |
N/A 20 A |
Minimum Circuit Ampacity |
N/A 13 A |
Compressor - Rated Load Amps |
N/A 10 A |
Compressor - Locked Rotor Amps |
N/A 52 A |
Condenser Fan Motor - Full Load Amps |
N/A 0.75 A |
Condenser Fan Motor - Locked Rotor Amps |
N/A 1.4 A |
Net Face Area - Outer Coil |
N/A 10.9 ft² |
Tube Diameter |
N/A 0.276 in |
Number of Rows |
N/A 1 |
Fins per Inch |
N/A 22 |
Outdoor Fan Diameter |
N/A 20 in |
Number of Blades |
N/A 3 |
Motor HP |
N/A 1/7 hp |
CFM |
N/A 2401 ft³/min |
RPM |
N/A 1075 |
Watts |
N/A 146 W |
Air Handler |
N/A H2TY2417STANN |
Total Capacity |
N/A 17100 Btu5 kW |
Net Sensible Capacity |
N/A 13100 Btu3.8 kW |
Net Latent Capacity |
N/A 4000 Btu1.2 kW |
SEER2 |
N/A 14.3 |
EER2 |
N/A 9.0 |
HSPF2 |
N/A 7.5 |
Indoor CFM |
N/A 625 ft³/min295 L/s |
Heating Capacity - 47°F |
N/A 16600 Btu5 kW |
Heating Capacity - 17°F |
N/A 10100 Btu3.3 kW |
COP - 47°F |
N/A 3.30 |
COP - 17°F |
N/A 2.40 |
Depth |
N/A 29.543 in750 mm |
Width |
N/A 29.543 in750 mm |
Height |
N/A 25.17 in639 mm |
Shipping Depth |
N/A 32.625 in829 mm |
Liquid Line O.D. |
N/A 3/8 in |
Suction Line O.D. |
N/A 3/4 in |
N/A
|