Friedrich Logo Background

CAD/BIM

  • Cooling & Heating Efficiency: 15.2 SEER2/11.7 EER2/7.8 HSPF2
  • Refrigerant Type: R-454B
  • Nominal Sizes: 1.5 to 5 Tons [TBD kW]
  • Cooling & Heating Capacities: 17.1 to 54 kBTU
  • Sound Ranking1: As low as 72 dB
  • ENERGY STAR® Certified2: Yes
  • EcoNet® Enabled: No
  • Compressor Type3: Two-Stage
  • Condenser Coil Type: 7mm
  • Features: Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
    Refrigerant Detection System™4: Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring
  • Limited Warranty*:
    Parts: 5 Years
    Conditional Compressor: 10 Years (registration required)

*For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
1Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product.
2Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR. Ask your contractor for details or visit EnergyStar.gov.
3The 1.5 ton model features a single-stage compressor.
4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).

Unit of Measure

Type

N/A Heat Pump

Nominal Capacity

N/A 48000 Btu14.07 kW4.0 TR

Refrigerant Type

N/A R-454B

Refrigerant Furnished oz.

N/A 115

Compressor Type

N/A Scroll

Sound Level

N/A 74 dB

Weight

N/A 253 lb

Voltage

N/A 208 to 230 V

Number of Phases

N/A 1

Frequency

N/A 60 Hz

Maximum Overcurrent Protection

N/A 45 A

Minimum Circuit Ampacity

N/A 27 A

Compressor - Rated Load Amps

N/A 20 A

Compressor - Locked Rotor Amps

N/A 141 A

Condenser Fan Motor - Full Load Amps

N/A 1.0 A

Condenser Fan Motor - Locked Rotor Amps

N/A 2.56 A

Net Face Area - Outer Coil

N/A 19.5 ft²

Tube Diameter

N/A 0.276 in

Number of Rows

N/A 1

Fins per Inch

N/A 24

Outdoor Fan Diameter

N/A 24 in

Number of Blades

N/A 3

Motor HP

N/A 1/5 hp

CFM

N/A 4096 ft³/min

RPM

N/A 850

Watts

N/A 236 W

Air Handler

N/A H2TY4821STANN

Total Capacity

N/A 45500 Btu13.3 kW

Net Sensible Capacity

N/A 34900 Btu10.2 kW

Net Latent Capacity

N/A 10600 Btu3.1 kW

SEER2

N/A 14.3

EER2

N/A 9.0

HSPF2

N/A 7.5

Indoor CFM

N/A 1450 ft³/min684.3 L/s

Heating Capacity - 47°F

N/A 44000 Btu13 kW

Heating Capacity - 17°F

N/A 27500 Btu8.1 kW

COP - 47°F

N/A 3.40

COP - 17°F

N/A 2.50

Depth

N/A 33.655 in855 mm

Width

N/A 33.655 in855 mm

Height

N/A 35.17 in893 mm

Shipping Depth

N/A 36.625 in930 mm

Liquid Line O.D.

N/A 3/8 in

Suction Line O.D.

N/A 7/8 in

N/A

  • Fully Louvered Steel Cabinet: Features durable construction to add protection from yard hazards and weather corrosion
  • Two-Stage Scroll Compressor1: Features two speeds (high and low) of cooling and heating, providing more precise temperature control, lower humidity and greater efficiency when compared to single stage compressors
  • Inverted Reversing Valve: Allows for faster heat transfer with gravity assist shifting and reduced joint stress for increased reliability
  • Expanded Valve Space: Provides a minimum working area of 27-square inches for easier access
  • Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%2 lower GWP than previous-generation refrigerants — with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
  • PlusOne® Refrigerant Detection System™: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation — if excess refrigerant is detected