CAD/BIM
- Cooling & Heating Efficiency: 15.2 SEER2/11.7 EER2/7.8 HSPF2
- Refrigerant Type: R-454B
- Nominal Sizes: 1.5 to 5 Tons [TBD kW]
- Cooling & Heating Capacities: 17.1 to 54 kBTU
- Sound Ranking1: As low as 72 dB
- ENERGY STAR® Certified2: Yes
- EcoNet® Enabled: No
- Compressor Type3: Two-Stage
- Condenser Coil Type: 7mm
- Features: Expanded Valve Space: Provides a minimum working area of 27-sqaure inches
Refrigerant Detection System™4: Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring - Limited Warranty*:
Parts: 5 Years
Conditional Compressor: 10 Years (registration required)
*For complete details of the limited and conditional warranties, including applicable terms and conditions, contact your local Contractor or go to Rheem.com for a copy of the product warranty certificate.
1Based on Internal R&D Testing, May 2022. Sound levels are also dependent on proper installation and location of outdoor product.
2Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR. Ask your contractor for details or visit EnergyStar.gov.
3The 1.5 ton model features a single-stage compressor.
4Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).
Type |
N/A Heat Pump |
Nominal Capacity |
N/A 60000 Btu17.58 kW5.0 TR |
Refrigerant Type |
N/A R-454B |
Refrigerant Furnished oz. |
N/A 194 |
Compressor Type |
N/A Scroll |
Sound Level |
N/A 74 dB |
Weight |
N/A 253 lb |
Voltage |
N/A 208 to 230 V |
Number of Phases |
N/A 1 |
Frequency |
N/A 60 Hz |
Maximum Overcurrent Protection |
N/A 50 A |
Minimum Circuit Ampacity |
N/A 33 A |
Compressor - Rated Load Amps |
N/A 25 A |
Compressor - Locked Rotor Amps |
N/A 147 A |
Condenser Fan Motor - Full Load Amps |
N/A 1.0 A |
Condenser Fan Motor - Locked Rotor Amps |
N/A 2.6 A |
Net Face Area - Outer Coil |
N/A 23.4 ft² |
Net Face Area - Inner Coil |
N/A 22.7 ft² |
Tube Diameter |
N/A 0.276 in |
Number of Rows |
N/A 2 |
Fins per Inch |
N/A 20 |
Outdoor Fan Diameter |
N/A 26 in |
Number of Blades |
N/A 3 |
Motor HP |
N/A 1/5 hp |
CFM |
N/A 4396 ft³/min |
RPM |
N/A 850 |
Watts |
N/A 284 W |
Air Handler |
N/A H2TY6021STANA |
Total Capacity |
N/A 54000 Btu15.8 kW |
Net Sensible Capacity |
N/A 41400 Btu12.1 kW |
Net Latent Capacity |
N/A 12600 Btu3.7 kW |
SEER2 |
N/A 14.3 |
EER2 |
N/A 9.0 |
HSPF2 |
N/A 7.5 |
Indoor CFM |
N/A 1650 ft³/min778.7 L/s |
Heating Capacity - 47°F |
N/A 54000 Btu16.3 kW |
Heating Capacity - 17°F |
N/A 32000 Btu10 kW |
COP - 47°F |
N/A 3.50 |
COP - 17°F |
N/A 2.50 |
Depth |
N/A 35.543 in903 mm |
Width |
N/A 35.543 in903 mm |
Height |
N/A 39.17 in995 mm |
Shipping Depth |
N/A 38.625 in981 mm |
Liquid Line O.D. |
N/A 3/8 in |
Suction Line O.D. |
N/A 7/8 in |
N/A
|