CAD/BIM
- Cooling Efficiency: 15.2 SEER2/11.5 EER2
- Refrigerant Type: R-454B
- Nominal Sizes 2 to 5 Tons [7.0 – 17.6 kW]
- Rated Cooling Capacities: 22.8 to 56 kBTU
- EcoNet® Enabled: No
- Compressor Type: Two-Stage Scroll
- Evaporator Coil Type: MicroChannel
- Condenser Coil Type: MicroChannel
- Airflow Type: Convertible
- Ultra Low NOx Option: No
- Low NOx Option: No
- 1-Phase Option: Yes
- 3-Phase Option: Yes
- Compatible Thermostat: Single-Stage 24V
- PlusOnes:
- PlusOne® Refrigerant Detection System™1- Integrated, patented
- Cooling Efficiency: 15.2 SEER2/11.5 EER2
- Refrigerant Type: R-454B
- Nominal Sizes 2 to 5 Tons [7.0 – 17.6 kW]
- Rated Cooling Capacities: 22.8 to 56 kBTU
- EcoNet® Enabled: No
- Compressor Type: Two-Stage Scroll
- Evaporator Coil Type: MicroChannel
- Condenser Coil Type: MicroChannel
- Airflow Type: Convertible
- Ultra Low NOx Option: No
- Low NOx Option: No
- 1-Phase Option: Yes
- 3-Phase Option: Yes
- Compatible Thermostat: Single-Stage 24V
- PlusOnes:
- PlusOne® Refrigerant Detection System™1- Integrated, patented design providing system protection and homeowner peace-of-mind with low GWP refrigerant monitoring
1Factory installed on 3.5, 4 and 5 ton models. For R-454B equipment with a refrigerant charge less than 3.9 lbs (≈1.8 kg or ≈62.6 oz), a refrigerant detection system is not required by the UL 60335-2-40 standard.
less
Unit of Measure
- Specifications
- Cooling Performance
- Compressor
- Outdoor Coil
- Indoor Coil
- Outdoor Fan
- Indoor Fan
- Filter
- Dimensions
- Features
Voltage |
N/A 208/230 V |
Frequency |
N/A 60 Hz |
Number of Phases |
N/A 1 |
Outdoor Sound Rating |
N/A 81 dB |
Refrigerant Charge |
N/A 81 oz2296 g |
Minimum Circuit Ampacity |
N/A 34 |
Minimum Overcurrent Protection Device Size |
N/A 50 |
Maximum Overcurrent Protection Device Size |
N/A 50 |
Shipping Weight |
N/A 465 lb211 kg |
Weight |
N/A 206 kg455 lb |
Nominal Cooling Capacity |
N/A 48500 Btu/h14.21 kW |
EER2 |
N/A 11.5 |
SEER2 |
N/A 15.2 |
Nominal CFM |
N/A 1600 ft³/min755 L/s |
AHRI Rated CFM |
N/A 1525 ft³/min720 L/s |
AHRI Net Cooling Capacity |
N/A 45500 Btu/h13.33 kW |
Net Sensible Cooling Capacity |
N/A 33300 Btu/h9.76 kW |
Net Latent Cooling Capacity |
N/A 14200 Btu/h4.16 kW |
Net System Power |
N/A 3.94 kW |
Type |
N/A Double-Stage Scroll |
No. Stages |
N/A 1 |
Fin Type |
N/A Louvered |
Tube Type |
N/A MicroChannel |
MicroChannel Depth |
N/A 1 in25.4 mm |
Face Area |
N/A 15.98 ft²1.48 m² |
Rows |
N/A 1 |
FPI |
N/A 23 |
Fin Type |
N/A Louvered |
Tube Type |
N/A MicroChannel |
MicroChannel Depth |
N/A 1 in25.4 mm |
Face Area |
N/A 7.07 ft²0.66 m² |
Rows |
N/A 1 |
FPI |
N/A 20 |
Refrigerant Control |
N/A TX Valves |
Drain Connection No. |
N/A 1 |
Drain Connection Size |
N/A 0.75 in19.05 mm |
Type |
N/A Propeller |
No. Used |
N/A 1 |
Diameter |
N/A 24 in609.6 mm |
Drive Type |
N/A Direct |
No. Speeds |
N/A 1 |
CFM |
N/A 4300 ft³/min2029 L/s |
No. Motors |
N/A 1 |
Horsepower |
N/A 1/3 hp |
Motor RPM |
N/A 1050 |
Type |
N/A FC Centrifugal |
No. Used |
N/A 1 |
Diameter |
N/A 12x9 in305x229 mm |
Drive Type |
N/A Direct |
No. Speeds |
N/A Multiple |
No. Motors |
N/A 1 |
Motor RPM |
N/A 1050 |
Motor Frame Size |
N/A 48 |
Type |
N/A Field Supplied |
Furnished |
N/A No |
No. Filters |
N/A 2 |
Recommended Size |
N/A 1x16x30 in25x406x762 mm |
Depth |
N/A 46 11/18 in |
Width |
N/A 55 25/32 in |
Height |
N/A 41 in |
N/A
1Bluetooth functionality applies to the heating section only. 2The BluetoothR word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by RheemR is under license. Other trademarks and trade names are those of their respective owners. 3Factory installed on 3.5, 4 and 5 ton models. For R-454B equipment with a refrigerant charge less than 3.9 lbs (≈1.8 kg or ≈62.6 oz), a refrigerant detection system is not required by the UL 60335-2-40 standard. 4When comparing the GWP of R-454B to R-410A refrigerant. |