Friedrich Logo Background

CAD/BIM

  • RACCYB

    • Nominal sizes: 3-6 Tons
    • 3-5 Tons: Up to 13.4 SEER2 / 10.6 EER2
    • 6 Tons: Up to 14.8 IEER / 11.2 EER
    • One-stage cooling (3 to 5 tons) or two-stage cooling (6 tons)
    • Coil Type: Full MicroChannel
    • Optional PlusOne® ClearControl™, PlusOne® HumidiDry®
    • Refrigerant Type: R-454B with factory-installed sensor

  • RACC

    • Nominal sizes: 3-6 Tons
    • 3-5 Tons: Up to 16.2 SEER2 / 12 EER2
    • 6 Tons: 14.8 IEER/11.2 EER
    • ZT Models: 2-stage cooling
    • ZR Models: 1-stage cooling
    • Convertible airflow – vertical downflow or horizontal sideflow
    • Coil Type: Full MicroChannel
    • Optional PlusOne® ClearControl™/Optional PlusOne® HumidiDry®

  • RACDYB

    • Nominal sizes: 7.5-12.5 Tons
    • Up to 11.2 EER / 14.8 IEER
    • Two-stage cooling
    • Coil Type: Full MicroChannel
    • Optional PlusOne® ClearControl™, PlusOne® HumidiDry®
    • Refrigerant Type: R-454B with factory-installed sensor

  • RACCZR/ZT

    • Factory charged with R-410A HFC refrigerant
    • Wired and run tested
    • Scroll compressors with internal line break overload and high pressure protection
    • Model RACDZR has a single-stage compressor
    • Models RACDZS and RACDZT have two-stage compressor
    • Convertible airflow – vertical down flow or horizontal side flow
    • Forkable base rails for easy handling and lifting
    • Cooling operation up to 125°F ambient
    • MicroChannel evaporator and condenser coil
    • PlusOne® ServiceSmart package includes:
      • Qwik-Change Flex-Fit Rack
      • Qwik-Slide Blower Assembly
      • Qwik-Clean Drain Pan
    • PlusOne® Diagnostics with Dual 7-Segment LED Display
    • One-piece top cover and one-piece base pan with drawn supply and return opening
    • Two-piece control door
    • 1/4 turn fasteners on filter access door
    • Color-coded and labeled wiring
    • External lockable external gauge ports
    • TXV refrigerant metering system
    • Solid-core liquid line filter drier
    • High pressure and low pressure/loss of charge protection
    • Insulation encapsulated throughout entire unit
    • High performance belt drive motor with variable pitch pulleys and quick adjust belt system
    • Variable Frequency Drive (VFD) blower is standard on Model RACDZT and optional on model RACDZS
    • New product footprint with matching connections
    • Improved factory lead times

  • RACG2T

    • Up to 14.2 IEER / 11 EER
    • Two-Stage Cooling
    • Two Return Air Configuration Options
    • Variable Frequency Drive
    • 3 Phase Models
    • PlusOne® Diagnostics CoreCommand™
    • PlusOne® ServiceSmart
    • PlusOne® SmartShield Coil System (excluding defrost system)
    • Nominal Sizes: 15-25 Tons

  • RACH5U.png

    • Up to 14.2 IEER / 10.5 EER
    • Standard Single-Zone and Multi-Zone VAV
    • Five-Stage Cooling
    • Variable Frequency Drive
    • 3 Phase Models
    • Convertible Airflow
    • PlusOne® ClearControl™
    • PlusOne® ServiceSmart
    • PlusOne® Diagnostics CoreCommand™
    • Nominal Size: 30 Tons

  • RLNL-G.png

    • Resolute™ RLNL-H and RLNL-G Models
    • Nominal sizes: 15-25 tons
    • Up to 11.0 EER/14.2 IEER
    • RLNL-H: Standard PlusOne® ClearControl™
    • RLNL-G: Standard PlusOne® ClearControl™ and HumidiDry®